You are here:
- Home
- Surge and Overvoltage
- TVSS / SPD
- CPS nano plus
- CPS nano plus 40 kA High Leg Delta 120 V
CPS nano plus 40 kA High Leg Delta 120 V
77797710

DPS-TVSS dispositivo protector de sobretensiones transitorias no-modular, UL , High Leg Delta 120V, 40kA, EMI filter, intelligent aging display IAD, remote indication, IP 66/NEMA 4.
Technical Data | Value | Units | |
---|---|---|---|
Commercial data | |||
Code | 77797710 | ||
Part Number | CPS nano plus 40 kA High Leg Delta 120 V | ||
Status | Available | ||
Tariff code (HS) | 8536.30.90 | ||
Dimensions | |||
Packaging height | 65 | [mm] | |
Packaging width | 107 | [mm] | |
Packaging length | 255 | [mm] | |
Packaging weight | 948 | [gr] | |
Product height | 203 | [mm] | |
Product width | 100 | [mm] | |
Product length | 51,5 | [mm] | |
Product weight | 890 | [gr] | |
General data | |||
Format | Non-modular (hardwired) | ||
Insulating material & flammability class | PC; V-0 | ||
Enclosure | IP 66 / NEMA 4 | ||
Temperature range | -40 ºC ... +70 ºC | ||
Technical features | |||
Surge modules | 7 | ||
Protected wires | 4W+G | ||
Product standards | UL 1449 3rd edition; IEC 61643-11 | ||
Certifications | CE; RCM | ||
Designation according to UL 1449 3rd Ed. | Type 2 | ||
Designation according to IEC 61643-11 | Class II | ||
Protection mode | Common & differential protection | ||
Nominal voltage AC 50-60 Hz (L-N) | Un (L-N) | 120 | [V] |
Nominal voltage AC 50-60 Hz (L-L) | Un (L-L) | 240 | [V] |
Nominal voltage AC 50-60 Hz (LHL-L) | Un (LHL-N) | 208 | [V] |
Maximum continuous operating voltage (L-N) | MCOV (L-N) | 175 | [V] |
Maximum continuous operating voltage (LHL-L) | MCOV (LHL-L) | 320 | [V] |
Maximum discharge current per phase (8/20) | Imax/Phase | 40 | [kA] |
Nominal discharge current per phase (8/20) | In/Phase | 10 | [kA] |
Voltage protection level (L-N) at In | VPR (L-N) | 600 | [V] |
Voltage protection level (L-G) at In | VPR (L-G) | 600 | [V] |
Voltage protection level (N-G) at In | VPR (N-G) | 600 | [V] |
Voltage protection level (L-L) at In | VPR (L-L) | 1200 | [V] |
Voltage protection level (LHL-N) at In | VPR (LHL-N) | 1000 | [V] |
Voltage protection level (LHL-G) at In | VPR (LHL-G) | 1000 | [V] |
Voltage protection level (LHL-L) at In | VPR (LHL-L) | 1600 | [V] |
Maximum back-up fuse | 63 | A [gG] | |
Short circuit withstand | SCCR | 100 | [kA] |
Response Time | tA | 1 | [ns] |
EMI filter | Yes | ||
Filter | ≤ 40 | [dB] | |
Multi-discharge system | MDS | Yes | |
Remote indication | Yes | ||
Protection status LED | Yes | ||
Intelligent aging display led | IAD | 100, 50, 0 | [%] |
Voltage LED | Yes | ||
Dynamic thermal disconnection | Yes | ||
Warranty | 5 years | ||
Wiring of connection circuit | |||
Flexible bare wire | 10 | [mm] | |
Max. flexible conductor section | 2,5 | [mm²] | |
Max. flexible conductor section | #14 | [AWG] |