{"id":28506,"date":"2018-04-11T11:16:00","date_gmt":"2018-04-11T11:16:00","guid":{"rendered":"https:\/\/www.cirprotec.com\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/"},"modified":"2026-06-11T13:27:20","modified_gmt":"2026-06-11T13:27:20","slug":"nouvelle-version-de-la-guide-rebt-itc-bt-23","status":"publish","type":"post","link":"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/","title":{"rendered":"Nouvelle version de la guide REBT ITC-BT-23"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"28506\" class=\"elementor elementor-28506 elementor-26816\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-53b685eb e-flex e-con-boxed e-con e-parent\" data-id=\"53b685eb\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-cfaa79d elementor-widget elementor-widget-text-editor\" data-id=\"cfaa79d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nouvelle \u00e9dition du Guide ITC-BT-23 du REBT en mati\u00e8re de protection contre les surtensions : \u00e9chelonnement, coordination de la protection et autres mesures de contr\u00f4le.<\/p><p>Au mois de novembre dernier, une <strong>nouvelle version du Guide de l\u2019Instruction Technique Compl\u00e9mentaire ITC-BT-23, \u00ab Installations int\u00e9rieures ou r\u00e9ceptrices. Protection contre les surtensions \u00bb<\/strong>, du R\u00e8glement \u00e9lectrotechnique basse tension (REBT), a \u00e9t\u00e9 publi\u00e9e.<\/p><h2><span style=\"color: #333333;\">Principales nouveaut\u00e9s de l\u2019ITC-BT-23 en mati\u00e8re de protection contre les surtensions<\/span><\/h2><p>L\u2019objectif principal de cette mise \u00e0 jour a \u00e9t\u00e9 de <strong>clarifier quand et comment prot\u00e9ger correctement contre les surtensions les installations \u00e9quip\u00e9es de paratonnerres<\/strong>, car l\u2019\u00e9dition pr\u00e9c\u00e9dente ne le pr\u00e9cisait pas, ce qui avait cr\u00e9\u00e9 une certaine confusion et un manque de protection dans ce type d\u2019installations.<\/p><p>La nouvelle \u00e9dition indique clairement <strong>l\u2019obligation de prot\u00e9ger, au moyen de dispositifs de protection contre les surtensions transitoires, les installations \u00e9quip\u00e9es de paratonnerres<\/strong>. Elle pr\u00e9cise notamment que ces dispositifs doivent \u00eatre de Type 1, conform\u00e9ment aux dispositions du SUA8, \u00ab S\u00e9curit\u00e9 face au risque caus\u00e9 par l\u2019action de la foudre \u00bb, du Code technique de la construction.<\/p><p><em>\u00ab Dans les installations de b\u00e2timents dot\u00e9s de syst\u00e8mes de protection externe contre la foudre \u2014 paratonnerres, pointes Franklin, cages de Faraday, etc. \u2014, conform\u00e9ment aux dispositions du CTE, SUA 8, et de l\u2019annexe B.2, les conducteurs des circuits \u00e9lectriques soumis \u00e0 la tension d\u2019alimentation du r\u00e9seau et les conducteurs des circuits de t\u00e9l\u00e9communication doivent \u00eatre prot\u00e9g\u00e9s au moyen de dispositifs de protection contre les surtensions transitoires install\u00e9s \u00e0 l\u2019origine de l\u2019installation du b\u00e2timent ; ceux-ci devront \u00eatre de Type 1. \u00bb<\/em><\/p><p>La nouvelle \u00e9dition introduit \u00e9galement <strong>d\u2019autres mesures pour le contr\u00f4le efficace des surtensions :<\/strong><\/p><ul><li>Elle rappelle <strong>l\u2019obligation d\u2019installer des protections contre les surtensions dans les installations de recharge de v\u00e9hicules \u00e9lectriques<\/strong>, conform\u00e9ment \u00e0 l\u2019ITC-BT-52.<br\/><em style=\"background-color: transparent;\"><br\/>\u00ab Par ailleurs, la nouvelle ITC-BT-52 inclut la n\u00e9cessit\u00e9 d\u2019une protection contre les surtensions dans les installations destin\u00e9es \u00e0 la recharge de v\u00e9hicules \u00e9lectriques. \u00bb<br\/><br\/><\/em><\/li><li><strong>Elle recommande l\u2019utilisation de protecteurs contre les surtensions transitoires de Type 3 pour les \u00e9quipements sensibles et de grande valeur<\/strong>, tels que les \u00e9quipements informatiques, les \u00e9crans plasma ou LED, les automates, les \u00e9quipements \u00e9lectroniques de machines industrielles, etc.<br><span style=\"background-color: transparent;\"><br><i>\u00ab Il est \u00e9galement recommand\u00e9 de tenir compte du co\u00fbt et de la sensibilit\u00e9 des \u00e9quipements, car plus un appareil est sensible et co\u00fbteux, plus il devrait b\u00e9n\u00e9ficier d\u2019une protection \u00e9lev\u00e9e. C\u2019est le cas des \u00e9quipements informatiques en g\u00e9n\u00e9ral, des \u00e9crans plasma ou LED, des appareils \u00e9lectrom\u00e9nagers de derni\u00e8re g\u00e9n\u00e9ration, des automates, des \u00e9quipements \u00e9lectroniques de machines industrielles, etc. Pour ces cas, la disposition des protections sera r\u00e9alis\u00e9e conform\u00e9ment aux dispositions du chapitre A de ce Guide, avec des dispositifs de protection contre les surtensions transitoires de Type 3. \u00bb<br><br><\/i><\/span><\/li><li>Les <strong>installations particuli\u00e8rement expos\u00e9es, telles que les installations ext\u00e9rieures<\/strong> \u2014 \u00e9clairage ext\u00e9rieur, photovolta\u00efque, etc. \u2014, n\u00e9cessitent <b>une protection contre les surtensions transitoires conform\u00e9ment au Guide BT-40.<br><\/b><span style=\"background-color: transparent;\"><b><br><\/b><i>\u00ab Pour les installations particuli\u00e8rement expos\u00e9es, telles que les installations ext\u00e9rieures \u2014 par exemple \u00e9clairage ext\u00e9rieur, photovolta\u00efques \u2014, l\u2019int\u00e9gration d\u2019un nombre plus important d\u2019\u00e9quipements et d\u2019\u00e9l\u00e9ments \u00e9lectroniques n\u00e9cessite l\u2019utilisation de dispositifs de protection contre les surtensions transitoires. Pour ces cas, la disposition des protections sera r\u00e9alis\u00e9e conform\u00e9ment aux dispositions du chapitre A de ce Guide, avec des dispositifs de protection contre les surtensions transitoires de Type 2. Les recommandations sp\u00e9cifiques pour la protection contre les surtensions des installations photovolta\u00efques sont fournies dans le Guide BT-40. \u00bb<br><br><\/i><\/span><\/li><\/ul><h2><span style=\"color: #333333;\">Installation et bonnes pratiques en mati\u00e8re de coordination des protections<\/span><\/h2><p>Dans de nombreuses installations, <strong>plus d\u2019un niveau de protection est n\u00e9cessaire<\/strong>. Cela permet d\u2019obtenir une <strong>plus grande capacit\u00e9 de d\u00e9charge tout en assurant une tension r\u00e9siduelle r\u00e9duite<\/strong>.<\/p><p>La nouvelle \u00e9dition renforce \u00e9galement le<strong> concept de protection en cascade et la coordination des protecteurs<\/strong> entre eux, en fixant une <strong>distance recommand\u00e9e de 10 m\u00e8tres entre les dispositifs<\/strong> afin d\u2019assurer cette coordination.<\/p><p><em>\u00ab En cas de n\u00e9cessit\u00e9 d\u2019installer plusieurs dispositifs de protection contre les surtensions transitoires en cascade \u2014 par exemple un dispositif g\u00e9n\u00e9ral ou principal et d\u2019autres sur certains circuits de sortie \u2014, il conviendra de consulter les informations d\u2019utilisation fournies par le fabricant afin d\u2019obtenir une coordination ad\u00e9quate. Dans les installations de grandes longueurs, disposant de tableaux secondaires ou permettant leur installation, il est recommand\u00e9 d\u2019installer des dispositifs de protection contre les surtensions transitoires de Type 2 suppl\u00e9mentaires tous les 10 m environ, conform\u00e9ment \u00e0 la norme UNE-CLC TS 61643-12. \u00bb<\/em><\/p><p>Ainsi, le premier niveau de protection s\u2019active en premier et d\u00e9rive la majeure partie de l\u2019\u00e9nergie. Le second niveau assure ensuite la fonction de r\u00e9duction de la tension r\u00e9siduelle. <\/p><p>Dans les tableaux o\u00f9 les deux niveaux de protection sont centralis\u00e9s et o\u00f9 il n\u2019existe pas de s\u00e9paration de 10 m, il convient d\u2019utiliser des <strong>dispositifs de protection combin\u00e9s<\/strong> ou d\u2019installer des <strong>bobines de d\u00e9couplage<\/strong> afin de simuler la distance de c\u00e2ble.<\/p><p>Par ailleurs \u2014 ind\u00e9pendamment de la distance minimale entre dispositifs pour assurer la coordination \u2014, la distance <strong>entre les dispositifs de protection et les \u00e9quipements \u00e0 prot\u00e9ger ne doit pas d\u00e9passer 10 m\u00e8tres<\/strong>. Dans le cas contraire, des oscillations et des champs \u00e9lectromagn\u00e9tiques peuvent se produire, augmentant la tension r\u00e9siduelle et endommageant les \u00e9quipements sensibles. Pour garantir cette distance maximale, il peut \u00eatre n\u00e9cessaire d\u2019installer plusieurs niveaux de protections en cascade, en respectant les principes de coordination mentionn\u00e9s pr\u00e9c\u00e9demment. <\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-87015d4 e-flex e-con-boxed e-con e-parent\" data-id=\"87015d4\" data-element_type=\"container\" data-e-type=\"container\" data-settings=\"{&quot;jet_parallax_layout_list&quot;:[]}\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-e737cab elementor-widget elementor-widget-button\" data-id=\"e737cab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.f2i2.net\/documentos\/lsiF2I2\/rbt\/guias\/guia_bt_23_nov17R3.pdf\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">Texte du Guide ITC-BT-23 novembre 2017<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Nouvelle \u00e9dition du Guide ITC-BT-23 du REBT en mati\u00e8re de protection contre les surtensions : \u00e9chelonnement, coordination de la protection et autres mesures de contr\u00f4le. Au mois de novembre dernier, une nouvelle version du Guide de l\u2019Instruction Technique Compl\u00e9mentaire ITC-BT-23, \u00ab Installations int\u00e9rieures ou r\u00e9ceptrices. Protection contre les surtensions \u00bb, du R\u00e8glement \u00e9lectrotechnique basse tension [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":26819,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"content-type":"","_searchwp_excluded":"","footnotes":""},"categories":[1992,1980],"tags":[],"class_list":["post-28506","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application","category-connaissance"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.8 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Nouvelle version de la guide REBT ITC-BT-23 - Cirprotec<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Nouvelle version de la guide REBT ITC-BT-23 - Cirprotec\" \/>\n<meta property=\"og:description\" content=\"Nouvelle \u00e9dition du Guide ITC-BT-23 du REBT en mati\u00e8re de protection contre les surtensions : \u00e9chelonnement, coordination de la protection et autres mesures de contr\u00f4le. Au mois de novembre dernier, une nouvelle version du Guide de l\u2019Instruction Technique Compl\u00e9mentaire ITC-BT-23, \u00ab Installations int\u00e9rieures ou r\u00e9ceptrices. Protection contre les surtensions \u00bb, du R\u00e8glement \u00e9lectrotechnique basse tension [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/\" \/>\n<meta property=\"og:site_name\" content=\"Cirprotec\" \/>\n<meta property=\"article:published_time\" content=\"2018-04-11T11:16:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-06-11T13:27:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.cirprotec.com\/wp-content\/uploads\/2025\/07\/ITC-BT-23.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"689\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Marta Martinez\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"Marta Martinez\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/nouvelle-version-de-la-guide-rebt-itc-bt-23\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/nouvelle-version-de-la-guide-rebt-itc-bt-23\\\/\"},\"author\":{\"name\":\"Marta Martinez\",\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/#\\\/schema\\\/person\\\/c6321bdaf1ef39da1f2df62ebe711578\"},\"headline\":\"Nouvelle version de la guide REBT ITC-BT-23\",\"datePublished\":\"2018-04-11T11:16:00+00:00\",\"dateModified\":\"2026-06-11T13:27:20+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/nouvelle-version-de-la-guide-rebt-itc-bt-23\\\/\"},\"wordCount\":973,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/nouvelle-version-de-la-guide-rebt-itc-bt-23\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.cirprotec.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/ITC-BT-23.png\",\"articleSection\":[\"Application\",\"Connaissance\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/nouvelle-version-de-la-guide-rebt-itc-bt-23\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/nouvelle-version-de-la-guide-rebt-itc-bt-23\\\/\",\"url\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/nouvelle-version-de-la-guide-rebt-itc-bt-23\\\/\",\"name\":\"Nouvelle version de la guide REBT ITC-BT-23 - Cirprotec\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/nouvelle-version-de-la-guide-rebt-itc-bt-23\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/nouvelle-version-de-la-guide-rebt-itc-bt-23\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.cirprotec.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/ITC-BT-23.png\",\"datePublished\":\"2018-04-11T11:16:00+00:00\",\"dateModified\":\"2026-06-11T13:27:20+00:00\",\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/nouvelle-version-de-la-guide-rebt-itc-bt-23\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/nouvelle-version-de-la-guide-rebt-itc-bt-23\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.cirprotec.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/ITC-BT-23.png\",\"contentUrl\":\"https:\\\/\\\/www.cirprotec.com\\\/wp-content\\\/uploads\\\/2025\\\/07\\\/ITC-BT-23.png\",\"width\":1200,\"height\":689},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/#website\",\"url\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/\",\"name\":\"Cirprotec\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/#organization\",\"name\":\"Cirprotec\",\"url\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.cirprotec.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/Logo-Cirprotec-by-Mersen.svg\",\"contentUrl\":\"https:\\\/\\\/www.cirprotec.com\\\/wp-content\\\/uploads\\\/2025\\\/12\\\/Logo-Cirprotec-by-Mersen.svg\",\"width\":284.53,\"height\":104.61,\"caption\":\"Cirprotec\"},\"image\":{\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.cirprotec.com\\\/fr\\\/#\\\/schema\\\/person\\\/c6321bdaf1ef39da1f2df62ebe711578\",\"name\":\"Marta Martinez\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0ea49a77b947f371075419e29eb01d04e287b6e11fcd840405b041322dffced5?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0ea49a77b947f371075419e29eb01d04e287b6e11fcd840405b041322dffced5?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/0ea49a77b947f371075419e29eb01d04e287b6e11fcd840405b041322dffced5?s=96&d=mm&r=g\",\"caption\":\"Marta Martinez\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Nouvelle version de la guide REBT ITC-BT-23 - Cirprotec","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/","og_locale":"fr_FR","og_type":"article","og_title":"Nouvelle version de la guide REBT ITC-BT-23 - Cirprotec","og_description":"Nouvelle \u00e9dition du Guide ITC-BT-23 du REBT en mati\u00e8re de protection contre les surtensions : \u00e9chelonnement, coordination de la protection et autres mesures de contr\u00f4le. Au mois de novembre dernier, une nouvelle version du Guide de l\u2019Instruction Technique Compl\u00e9mentaire ITC-BT-23, \u00ab Installations int\u00e9rieures ou r\u00e9ceptrices. Protection contre les surtensions \u00bb, du R\u00e8glement \u00e9lectrotechnique basse tension [&hellip;]","og_url":"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/","og_site_name":"Cirprotec","article_published_time":"2018-04-11T11:16:00+00:00","article_modified_time":"2026-06-11T13:27:20+00:00","og_image":[{"width":1200,"height":689,"url":"https:\/\/www.cirprotec.com\/wp-content\/uploads\/2025\/07\/ITC-BT-23.png","type":"image\/png"}],"author":"Marta Martinez","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"Marta Martinez","Dur\u00e9e de lecture estim\u00e9e":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/#article","isPartOf":{"@id":"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/"},"author":{"name":"Marta Martinez","@id":"https:\/\/www.cirprotec.com\/fr\/#\/schema\/person\/c6321bdaf1ef39da1f2df62ebe711578"},"headline":"Nouvelle version de la guide REBT ITC-BT-23","datePublished":"2018-04-11T11:16:00+00:00","dateModified":"2026-06-11T13:27:20+00:00","mainEntityOfPage":{"@id":"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/"},"wordCount":973,"commentCount":0,"publisher":{"@id":"https:\/\/www.cirprotec.com\/fr\/#organization"},"image":{"@id":"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/#primaryimage"},"thumbnailUrl":"https:\/\/www.cirprotec.com\/wp-content\/uploads\/2025\/07\/ITC-BT-23.png","articleSection":["Application","Connaissance"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/","url":"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/","name":"Nouvelle version de la guide REBT ITC-BT-23 - Cirprotec","isPartOf":{"@id":"https:\/\/www.cirprotec.com\/fr\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/#primaryimage"},"image":{"@id":"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/#primaryimage"},"thumbnailUrl":"https:\/\/www.cirprotec.com\/wp-content\/uploads\/2025\/07\/ITC-BT-23.png","datePublished":"2018-04-11T11:16:00+00:00","dateModified":"2026-06-11T13:27:20+00:00","inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.cirprotec.com\/fr\/nouvelle-version-de-la-guide-rebt-itc-bt-23\/#primaryimage","url":"https:\/\/www.cirprotec.com\/wp-content\/uploads\/2025\/07\/ITC-BT-23.png","contentUrl":"https:\/\/www.cirprotec.com\/wp-content\/uploads\/2025\/07\/ITC-BT-23.png","width":1200,"height":689},{"@type":"WebSite","@id":"https:\/\/www.cirprotec.com\/fr\/#website","url":"https:\/\/www.cirprotec.com\/fr\/","name":"Cirprotec","description":"","publisher":{"@id":"https:\/\/www.cirprotec.com\/fr\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.cirprotec.com\/fr\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.cirprotec.com\/fr\/#organization","name":"Cirprotec","url":"https:\/\/www.cirprotec.com\/fr\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.cirprotec.com\/fr\/#\/schema\/logo\/image\/","url":"https:\/\/www.cirprotec.com\/wp-content\/uploads\/2025\/12\/Logo-Cirprotec-by-Mersen.svg","contentUrl":"https:\/\/www.cirprotec.com\/wp-content\/uploads\/2025\/12\/Logo-Cirprotec-by-Mersen.svg","width":284.53,"height":104.61,"caption":"Cirprotec"},"image":{"@id":"https:\/\/www.cirprotec.com\/fr\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.cirprotec.com\/fr\/#\/schema\/person\/c6321bdaf1ef39da1f2df62ebe711578","name":"Marta Martinez","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/0ea49a77b947f371075419e29eb01d04e287b6e11fcd840405b041322dffced5?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/0ea49a77b947f371075419e29eb01d04e287b6e11fcd840405b041322dffced5?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/0ea49a77b947f371075419e29eb01d04e287b6e11fcd840405b041322dffced5?s=96&d=mm&r=g","caption":"Marta Martinez"}}]}},"_links":{"self":[{"href":"https:\/\/www.cirprotec.com\/fr\/wp-json\/wp\/v2\/posts\/28506","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.cirprotec.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.cirprotec.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.cirprotec.com\/fr\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/www.cirprotec.com\/fr\/wp-json\/wp\/v2\/comments?post=28506"}],"version-history":[{"count":1,"href":"https:\/\/www.cirprotec.com\/fr\/wp-json\/wp\/v2\/posts\/28506\/revisions"}],"predecessor-version":[{"id":28507,"href":"https:\/\/www.cirprotec.com\/fr\/wp-json\/wp\/v2\/posts\/28506\/revisions\/28507"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.cirprotec.com\/fr\/wp-json\/wp\/v2\/media\/26819"}],"wp:attachment":[{"href":"https:\/\/www.cirprotec.com\/fr\/wp-json\/wp\/v2\/media?parent=28506"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.cirprotec.com\/fr\/wp-json\/wp\/v2\/categories?post=28506"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.cirprotec.com\/fr\/wp-json\/wp\/v2\/tags?post=28506"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}